{"id":16070,"date":"2026-11-20T10:47:52","date_gmt":"2026-11-20T07:47:52","guid":{"rendered":"https:\/\/www.inetmar.com\/blog\/?p=16070"},"modified":"2026-11-20T10:56:09","modified_gmt":"2026-11-20T07:56:09","slug":"vmware-vcenter-guvenlik-acigi-cve-2026-123890","status":"publish","type":"post","link":"https:\/\/www.inetmar.com\/blog\/vmware-vcenter-guvenlik-acigi-cve-2026-123890\/","title":{"rendered":"Kritik VMware vCenter G\u00fcvenlik A\u00e7\u0131\u011f\u0131 (CVE-2026-123890): Sald\u0131rganlar Kimlik Do\u011frulamay\u0131 Atlatabiliyor!"},"content":{"rendered":"<p>Broadcom, b\u00fcnyesinde bulunan VMware vCenter\u2019da tespit edilen ve sald\u0131rganlar\u0131n kimlik do\u011frulama mekanizmas\u0131n\u0131 atlatarak sisteme yetkisiz eri\u015fim sa\u011flamas\u0131na olanak tan\u0131yan kritik bir g\u00fcvenlik a\u00e7\u0131\u011f\u0131 <strong>CVE-2026-123890<\/strong> i\u00e7in acil durum yamas\u0131 yay\u0131nlad\u0131. Desteklenen t\u00fcm s\u00fcr\u00fcmler i\u00e7in g\u00fcncellemeler kullan\u0131ma sunuldu.<\/p>\n<h2>CVSS Puan\u0131 9.8<\/h2>\n<p>Kurumlar\u0131n ESX ana bilgisayarlar\u0131n\u0131 ve sanal makinelerini y\u00f6netti\u011fi merkezi konsol olan vCenter&#8217;daki <strong>CVE-2026-123890<\/strong> kodlu bu g\u00fcvenlik a\u00e7\u0131\u011f\u0131, CVSS derecelendirme sisteminde 10 \u00fczerinden <strong>9.8<\/strong> gibi olduk\u00e7a kritik bir puana sahip. Broadcom\u2019un yay\u0131nlad\u0131\u011f\u0131 g\u00fcvenlik b\u00fcltenine g\u00f6re zafiyet, do\u011frudan VMware Dizin Hizmeti&#8217;ndeki (VMware Directory Service) bir kimlik do\u011frulama atlatma hatas\u0131ndan kaynaklan\u0131yor.<\/p>\n<p>\u015eirket, yay\u0131nlad\u0131\u011f\u0131 S\u0131k\u00e7a Sorulan Sorular belgesinde durumu ITIL metodolojileri kapsam\u0131nda &#8220;acil de\u011fi\u015fiklik&#8221; (emergency change) olarak nitelendirdi ve kurumlar\u0131n yama takvimi i\u00e7in vakit kaybetmeden g\u00fcvenlik ekipleriyle ileti\u015fime ge\u00e7mesi gerekti\u011fini vurgulad\u0131.<\/p>\n<h2>Yama Yay\u0131nlanmadan \u0130ki Ay \u00d6nce \u0130stismar Edildi<\/h2>\n<p>Google Tehdit \u0130stihbarat\u0131 ekibinin 20 Kas\u0131m&#8217;da yay\u0131nlad\u0131\u011f\u0131 teknik analize g\u00f6re s\u00f6z konusu a\u00e7\u0131k, yama yay\u0131nlanmadan iki aydan daha uzun bir s\u00fcre \u00f6nce zero-day zafiyeti olarak sald\u0131rganlar taraf\u0131ndan aktif bi\u00e7imde kullan\u0131ld\u0131.<\/p>\n<p>Google b\u00fcnyesindeki Mandiant taraf\u0131ndan raporlanan bu a\u00e7\u0131\u011f\u0131n, \u00c7in ba\u011flant\u0131l\u0131 oldu\u011fundan \u015f\u00fcphelenilen <strong>Armory Castle<\/strong> adl\u0131 bir siber casusluk grubu taraf\u0131ndan Eyl\u00fcl ay\u0131 ba\u015flar\u0131nda kullan\u0131ld\u0131\u011f\u0131 tespit edildi. Sald\u0131rganlar\u0131n, daha \u00f6nce s\u0131zd\u0131klar\u0131 bir a\u011f i\u00e7erisindeki vCenter sunucusunda administrator yetkisi elde etmek i\u00e7in bu zafiyetten faydaland\u0131\u011f\u0131 belirtiliyor.<\/p>\n<h2>Hangi S\u00fcr\u00fcmler Etkileniyor?<\/h2>\n<p>G\u00fcvenlik a\u00e7\u0131\u011f\u0131 geni\u015f bir \u00fcr\u00fcn yelpazesini tehdit ediyor:<\/p>\n<ul>\n<li><strong>vCenter S\u00fcr\u00fcmleri:<\/strong> 8.0, 9.0 ve 9.1<\/li>\n<li><strong>Di\u011fer \u00dcr\u00fcnler:<\/strong> VMware Cloud Foundation (eski 5.x serisi dahil), vSphere Foundation, Telco Cloud Platform ve Telco Cloud Infrastructure i\u00e7erisindeki vCenter yap\u0131lar\u0131. <em>(Zafiyet, Geli\u015fmi\u015f Ba\u011flant\u0131l\u0131 Mod&#8217;un (Enhanced Linked Mode) aktif olup olmamas\u0131ndan ba\u011f\u0131ms\u0131z olarak t\u00fcm sistemleri etkiliyor.)<\/em><\/li>\n<li><strong>Deste\u011fi Biten S\u00fcr\u00fcmler:<\/strong> Broadcom art\u0131k deste\u011fi sona eren s\u00fcr\u00fcmleri test etmedi\u011fini belirterek <strong>vSphere 6.5 ve 6.7<\/strong> s\u00fcr\u00fcmlerinin de bu a\u00e7\u0131ktan etkilendi\u011finin varsay\u0131lmas\u0131 gerekti\u011fini duyurdu. Ekim 2025&#8217;te genel deste\u011fi sona eren <strong>vSphere 7.0<\/strong> kullan\u0131c\u0131lar\u0131 ise yaln\u0131zca geni\u015fletilmi\u015f destek s\u00f6zle\u015fmeleri kapsam\u0131nda yama talep edebilecek.<\/li>\n<\/ul>\n<p>B\u00fcltende payla\u015f\u0131lan sevindirici tek detay ise, a\u00e7\u0131klanan be\u015f g\u00fcvenlik a\u00e7\u0131\u011f\u0131n\u0131n hi\u00e7birinin sanal makine i\u00e7erisinden ESX ana bilgisayar\u0131 \u00fczerinde kod \u00e7al\u0131\u015ft\u0131rmaya izin vermemesi ve ESX\u2019in do\u011frudan bu durumdan etkilenmemesi oldu.<\/p>\n<h2>G\u00fcncelleme Yaparken Dikkat Edilmesi Gereken Kritik Uyar\u0131lar<\/h2>\n<p>Broadcom, hen\u00fcz g\u00fcncelleme yapamayan sistemler i\u00e7in resmi bir ge\u00e7ici \u00e7\u00f6z\u00fcm sunmad\u0131\u011f\u0131n\u0131, ancak kurumlar\u0131n kendi savunma katmanlar\u0131nda baz\u0131 \u00f6nlemler alabilece\u011fini ifade ediyor. Yama s\u00fcrecinde sistem y\u00f6neticilerinin dikkat etmesi gereken teknik detaylar ise \u015f\u00f6yle:<\/p>\n<ul>\n<li><strong>K\u00fcm\u00fclatif G\u00fcncelleme ve Kesinti:<\/strong> Yay\u0131nlanan yamalar k\u00fcm\u00fclatif yap\u0131da oldu\u011fu i\u00e7in <em>vCenter Quick Patch<\/em> arac\u0131yla y\u00fcklenemiyor. Kurulum s\u0131ras\u0131nda sanal makineler \u00e7al\u0131\u015fmaya devam etse de y\u00f6netim eri\u015fimi k\u0131sa s\u00fcreli\u011fine kesiliyor ve vCenter tekrar \u00e7evrimi\u00e7i olana kadar Standart Anahtar Sa\u011flay\u0131c\u0131 (Standard Key Provider) \u00fczerindeki baz\u0131 \u015fifreleme i\u015flemleri devre d\u0131\u015f\u0131 kal\u0131yor.<\/li>\n<li><strong>S\u00fcr\u00fcm \u00c7ak\u0131\u015fmas\u0131 (&#8220;Back-in-Time&#8221; Sorunu):<\/strong> Halihaz\u0131rda y\u00fckseltme plan\u0131 yapan y\u00f6neticiler i\u00e7in kritik bir uyar\u0131 mevcut. <strong>vCenter 8.0 U3m<\/strong> veya <strong>9.0.2.0200<\/strong> s\u00fcr\u00fcmlerini y\u00fcklemek, daha sonra <em>VMware Cloud Foundation 9.1.1<\/em> s\u00fcr\u00fcm\u00fcne ge\u00e7i\u015fi engelliyor. Broadcom, bu \u00e7ak\u0131\u015fmay\u0131 \u00f6nlemek i\u00e7in \u00f6nce vCenter&#8217;\u0131n 9.1.1 s\u00fcr\u00fcm\u00fcne y\u00fckseltilip ard\u0131ndan g\u00fcvenlik yamas\u0131n\u0131n uygulanmas\u0131n\u0131 ya da k\u0131sa s\u00fcre i\u00e7inde yay\u0131nlanacak VCF 9.1.2 s\u00fcr\u00fcm\u00fcn\u00fcn beklenmesini \u00f6neriyor.<\/li>\n<\/ul>\n<h2>VMware Directory Service&#8217;deki \u0130kinci B\u00fcy\u00fck Vaka<\/h2>\n<p>CVE-2026-123890, VMware Dizin Hizmeti&#8217;nde bu y\u0131l tespit edilen ikinci kritik kimlik do\u011frulama a\u00e7\u0131\u011f\u0131 olma \u00f6zelli\u011fini ta\u015f\u0131yor. 29 Temmuz&#8217;da yay\u0131nlanan \u00f6nceki yamalarda da yine ayn\u0131 bile\u015fende 9.8 puanl\u0131 <strong>CVE-2026-59309<\/strong> a\u00e7\u0131\u011f\u0131 ile birlikte <strong>CVE-2026-59310<\/strong> kodlu bir directory-traversal zafiyeti kapat\u0131lm\u0131\u015ft\u0131. Alman olay m\u00fcdahale firmas\u0131 QUIRSO&#8217;nun A\u011fustos raporuna g\u00f6re, Temmuz ay\u0131ndaki bu a\u00e7\u0131klar\u0131n duyurulmas\u0131ndan sadece be\u015f g\u00fcn sonra \u00c7in ba\u011flant\u0131l\u0131 tehdit akt\u00f6rleri harekete ge\u00e7mi\u015f; 47 \u00fclkede yakla\u015f\u0131k 361 IP adresini ele ge\u00e7irerek ESXi sunucular\u0131na Babuk tabanl\u0131 fidye yaz\u0131l\u0131mlar\u0131 bula\u015ft\u0131rm\u0131\u015ft\u0131.<\/p>\n<h2>B\u00fcltendeki Di\u011fer G\u00fcvenlik A\u00e7\u0131klar\u0131<\/h2>\n<p>Broadcom, kritik zafiyetin yan\u0131 s\u0131ra CVSS puanlar\u0131 6.7 ile 8.1 aras\u0131nda de\u011fi\u015fen d\u00f6rt farkl\u0131 g\u00fcvenlik a\u00e7\u0131\u011f\u0131n\u0131 daha kapatt\u0131. Tamam\u0131 halihaz\u0131rda kimlik do\u011frulamas\u0131 yapm\u0131\u015f veya yetki sahibi sald\u0131rganlar gerektiren bu a\u00e7\u0131klar \u015funlar:<\/p>\n<ul>\n<li><strong>CVE-2026-123891:<\/strong> SDDC Manager&#8217;da SQL enjeksiyonu.<\/li>\n<li><strong>CVE-2026-123892:<\/strong> SDDC Manager&#8217;da komut enjeksiyonu.<\/li>\n<li><strong>CVE-2026-123893:<\/strong> SDDC Manager cihaz\u0131nda root seviyesine yetki y\u00fckseltme.<\/li>\n<li><strong>CVE-2026-123894:<\/strong> Windows i\u00e7in VMware Tools&#8217;ta SAML belirteci imza atlatma (Yaln\u0131zca <em>Guest Alias<\/em> e\u015flemesi yap\u0131land\u0131r\u0131lm\u0131\u015f sistemlerde ve sanal makine s\u0131n\u0131rlar\u0131 i\u00e7inde istismar edilebiliyor).<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Broadcom, b\u00fcnyesinde bulunan VMware vCenter\u2019da tespit edilen ve sald\u0131rganlar\u0131n kimlik do\u011frulama mekanizmas\u0131n\u0131 atlatarak sisteme yetkisiz eri\u015fim sa\u011flamas\u0131na olanak tan\u0131yan kritik bir g\u00fcvenlik a\u00e7\u0131\u011f\u0131 CVE-2026-123890 i\u00e7in acil durum yamas\u0131 yay\u0131nlad\u0131. Desteklenen t\u00fcm s\u00fcr\u00fcmler i\u00e7in g\u00fcncellemeler kullan\u0131ma sunuldu. CVSS Puan\u0131 9.8 Kurumlar\u0131n ESX ana bilgisayarlar\u0131n\u0131 ve sanal makinelerini y\u00f6netti\u011fi merkezi konsol olan vCenter&#8217;daki CVE-2026-123890 kodlu bu g\u00fcvenlik &hellip;<\/p>\n","protected":false},"author":2,"featured_media":16076,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[52,46],"tags":[1780,1775,1773,1779,1778,1772,1777,1774,1776],"class_list":["post-16070","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-guvenlik","category-sunucu","tag-2026-cve-list","tag-cve-2026-123890","tag-esxi-cve","tag-esxi-cve-2026","tag-esxi-cve-list","tag-vcenter-cve","tag-vcenter-cve-list","tag-vmware-cve","tag-vmware-vcenter-cve"],"_links":{"self":[{"href":"https:\/\/www.inetmar.com\/blog\/wp-json\/wp\/v2\/posts\/16070","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.inetmar.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.inetmar.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.inetmar.com\/blog\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.inetmar.com\/blog\/wp-json\/wp\/v2\/comments?post=16070"}],"version-history":[{"count":5,"href":"https:\/\/www.inetmar.com\/blog\/wp-json\/wp\/v2\/posts\/16070\/revisions"}],"predecessor-version":[{"id":16077,"href":"https:\/\/www.inetmar.com\/blog\/wp-json\/wp\/v2\/posts\/16070\/revisions\/16077"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.inetmar.com\/blog\/wp-json\/wp\/v2\/media\/16076"}],"wp:attachment":[{"href":"https:\/\/www.inetmar.com\/blog\/wp-json\/wp\/v2\/media?parent=16070"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.inetmar.com\/blog\/wp-json\/wp\/v2\/categories?post=16070"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.inetmar.com\/blog\/wp-json\/wp\/v2\/tags?post=16070"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}